CEH logo - Return to the homepage

[ Skip to content ] [ View sitemap ]

CFT heavy duty tubular heaters 300W to 2000W

Product image





Applications

A range of very robust tubular heaters for heating applications where a waterproof heavy duty convector heater is required. Can be used in applications where washing down may occur. Typical locations include Dairies, Food storage, Mines and Quarries, Shipboard, Container storage, Kennels, Catteries, Zoos, Greenhouses and Plant/Lift rooms.

Back to top Back to top


Features

  • very robust construction
  • heavy duty finned steel tube
  • reliable mineral insulated metal sheathed element
  • matt black high temperature powder coated finish
  • suitable for floor or wall mounting ( must be horizontal )
  • large terminal box for easy connections
  • terminal box welded to tube and sealed to IP65
  • slotted fixings for easier positioning
  • 230V and 110V units available
  • special 24V 250W unit for mobile and small boat applications.

Back to top Back to top


Options

  • remote exterior frost thermostat to IP65 (CXFST)
  • remote interior frost thermostat (CFST)
  • remote interior room thermostat (CRST)
  • remote interior room thermostat - tamperproof (CTRT)
  • wire guard for added safety (CWG- )

Back to top Back to top


Specification

Cat No Watts Volt Length L mm Fix Cent C mm Wt kg Wire Guard Guard W mm
CFT-0252 250 24 360 253 4.2 CWG-0300 400
CFT-0300 300 230 360 253 4.2 CWG-0300 400
CFT-0500 500 230 585 478 7.0 CWG-0500 600
CFT-0750 750 230 810 703 9.8 CWG-0750 850
CFT-1000 1000 230 1035 928 12.6 CWG-1000 1100
CFT-1500 1500 230 1485 1378 18.3 CWG-1500 1550
CFT-2000 2000 230 1935 1828 23.9 CWG-2000 2000
CFT-0301 300 110 360 253 4.2 CWG-0300 400
CFT-0501 500 110 585 478 7.0 CWG-0500 600
CFT-0751 750 110 810 703 9.8 CWG-0750 850
CFT-1001 1001 110 1035 928 12.6 CWG-1000 1100
CFT-1501 1500 110 1485 1378 18.3 CWG-1500 1550
CFT-2001 2000 110 1485 1378 18.3 CWG-1500 1550


Back to top Back to top


Installation

CFT heaters must be mounted horizontally and must not be covered.

Although surface temperatures may be considered acceptable for most applications, the optional wire guard is recommended in areas where contact with the hot surface is to be avoided, for example animal enclosures or tight spaces such as crane cabs etc.

Electrical connection is made via a 20mm hole to easily accessible screw terminals inside the connection box.

Electrical installation should be by a suitably qualified person in accordance with the latest edition of the IEE Requirements for Electrical Installation (BS 7671:1992).

If installed in wet conditions suitable glands must be used to ensure IP65 integrity is maintained.

Air temperature control, if required, is by remote thermostat.

Back to top Back to top


Thermostats

Cat No Thermostat Type Range Amp 230Vac H mm W mm D mm
CXFST Exterior frost (IP65) -50C/250C 10 120 160 75
CFST Interior Frost +10C/+200C 16 79 75 45
CRST16 Interior Room +100C/+300C 16 84 84 40
CTRT
Tamperproof interior room
+60C/+300C 16 72 72 45
CPRST
Programmable interior room
+50C/+350C 5 84 84 32

Back to top Back to top